โ ๏ธ Latest Violations (7)
Unknown
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: 4-501.11: OBSERVED DAMAGED GASKETS ON BOTH DOORS OF SMALL TWO DOOR COLD HOLDING UNIT IN FRONT PREP AREA ACROSS FROM FLAT TOP GRILL NEXT TO OVEN. INSTRUCTEDTO REPAIR/REPLACE DAMAGED GASKETS ON BOTH DOORS OF SMALL TWO DOOR COLD HOLDING UNIT IN FRONT PREP AREA ACROSS FROM FLAT TOP GRILL NEXT TO OVEN AND MAINTAIN.
Unknown
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: 4-101.19: OBSERVED RUST ON BOTH SHELVING UNITS IN WALK IN COOLER. INSTRUCTED TO REMOVE RUST FROM BOTH SHELVING UNITS IN WALK IN COOLER, NONFOOD CONTACT SURFACES OF EQUIPMENT SHALL BE CONSTRUCTED OF A CORROSION RESISTANT, NONABSORBENT AND SMOOTH MATERIAL.
Unknown
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: 4-101.13(C): CERAMIC/CLAY DRINKING CUPS AND BOWLS ON SITE. INSTRUCTED TO ENSURE CUPS AND BOWLS ARE LEAD-FREE OR CONTAIN LEAD-SAFE LEVELS AND MAINTAIN DOCUMENTATION OF SUCH ON-SITE OR REMOVE FROM PREMISES.
Unknown
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: 5-204.12: UNABLE TO LOCATE BACKFLOW PREVENTION DEVICE ON UTILITY SINK. INSTRUCTED TO INSTALL BACKFLOW PREVENTION DEVICE ON UTILITY SINK SO THAT IT SHALL BE LOCATED SO THAT IT MAY BE SERVICED AND MAINTAINED.
Unknown
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: 4-301.16: OBSERVED NO PREP/DUMP SINK IN BEVERAGE STATION. INSTRUCTED TO INSTALL A PREP/DUMP SINK IN BEVERAGE STATION A MINIMUM OF ONE SINK USED FOR FOOD PREPARATION, OBTAINING WATER AND DISCARDING LIQUID WASTE IS REQUIRED IN ANY PREPARATION AREA.
Unknown
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN - Comments: 6-501.11: OBSERVED MISSING OR DAMAGED FLOOR TILES IN FRONT PREP AREA AND IN REAR PREP/DISHWASHING AREA. INSTRUCTED TO SMOOTHLY REPAIR OR REPLACE ALL DAMAGED OR MISSING FLOOR TILES FOR EASE OF CLEANABILITY. OBSERVED STAINED CEILING TILES IN BOTH WASHROOMS. INSTRUCTED TO REPLACE ALL STAINED CEILING TILES IN BOTH WASHROOMS AND MAINTAIN.
Unknown
ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED - Comments: 6-501.14: OBSERVED DUST ON VENTS IN BOTH HOODS IN FRONT PREP AREA. INSTRUCTED TO CLEAN VENTS IN BOTH HOODS IN FRONT PREP AREA AND MAINTAIN.